CTD Processing Summary CalCOFI 0604NH CTD Final Data (reprocessed/reformatted 03/2019) | |||||||||||||||||||||
Download 0604NH CTD raw cast files zipped | Download 0604NH FinalQC CTD + bottle data | ||||||||||||||||||||
General CTD Notes - data acquisition cast notes, logistics, processing notes are listed below | |||||||||||||||||||||
CTD sensor corrections derived by comparing 4 secs of CTD sensor data (prior to bottle closure) to bottle samples | |||||||||||||||||||||
Dual T & S | Primary Sensor | Secondary Sensor | |||||||||||||||||||
Temperature, dual SBE3 | No offset or correction | No offset or correction | |||||||||||||||||||
Salinity offset (bottle - CTD salinity; > 350m only; Seabird SBE4; fliers excluded) | -0.0051 | -0.0057 | |||||||||||||||||||
Single sensors - note only one CTD O2 sensor ml/L uM/Kg | |||||||||||||||||||||
Oxygen (ml/L & uM/Kg; single Seabird SBE43) |
y = 1.1759x - 0.1087 R² = 0.9994 |
y = 1.1759x - 4.7315 R² = 0.9994 |
|||||||||||||||||||
Satlantic MBARI-ISUS (SN#111 v2) deployed |
y = 27.268x - 9.1806 R² = 0.9982 |
||||||||||||||||||||
Seapoint Fluorometer - linear & polynomial regressions |
y = 4.3969x - 0.233 R² = 0.7658 |
y = 1.3938x2+ 2.6874x - 0.054 |
|||||||||||||||||||
|
|
||||||||||||||||||||
General notes: Station Pattern & Cruise Track
|
|||||||||||||||||||||
CalCOFI 0604NH • 01 - 18 April 2006 • SIO RV New Horizon • San Diego to San DiegoCruise and CTD Data Processing Notes CalCOFI 0604NH on SIO RV New Horizon successfully occupied all 75 of 75 scheduled stations - 66 standard stations & 9 SCCOOS 20m stations. Acoustic calbration was not performed in San Diego Bay so day 1's primary productivity experiment was performed on the 1st station 93.3 26.7..
Seabird 911+ configuration:
|
|||||||||||||||||||||
CalCOFI 0604NH CTD Data Processing & Console Ops Notes Removed salt fliers on both primary & secondary comparisons. Removed O2 fliers on regression plots. A deep CTD casts to ~770m was NOT performed at sta 86.7 40.0 Cast 036 Santa Monica Basin this cruise - normal 515m cast. Only one O2 sensor was deployed and a SBE11v1 Deck Unit - requiring Align-CTD offset of secondary conductivity (0.073sec) was used.
General Notes: We started data acquisition AFTER deploying and 2 minutes @10m soak. Loopedit was not applied to any cast.
Transmissometer important note:
M = 19.02946434 JRW 03/01/2019 |